Incinolet Toilet Questions

What power does the Incinolet need?

A dedicated 20 amp circuit. Choose 120 V at about 2000 W or 240 V at about 3500 W.

How many people can it support full time?

120 V model is about 4 people, 240 V model is about 6 people.

Does it use water or need a septic system?

No. It incinerates waste using electric heat and vents outside. 

Do I need a bowl liner every time?

Yes, for every use. New units include one box of 200 liners. Bowl Liners can be purchased here.

How long is a cycle and can I use it during the cycle?

Heater runs about 60 to 75 minutes, the blower continues 20 to 40 minutes to cool. You can use it any time during a cycle, then press Start again. 

How much electricity per cycle?

About 1.5 to 2.0 kWh per full cycle. Example at $0.20 per kWh is roughly $0.30 to $0.40 per cycle. 

What can go in the toilet?

Human waste, toilet paper, and tampons. Do not burn trash or food. Use a liner each time. 

How do I vent it?

Horizontal or vertical to outdoors, end with a dryer flap or rain cap. If total run is over 10 feet or uses more than two elbows, increase to 6 inch pipe, 15 feet max. Do not vent into an attic or crawl space. 

Will there be odours?

Little to none with correct venting and by starting a cycle after each use. Overloading or poor venting can cause odor. 

What happens during a power outage?

If a cycle stops mid-burn you may notice smoke or odour. Open a window. When power returns the fan restarts to cool the unit. 

How often do I empty the ash and how do I dispose of it?

Empty when ash is light in color or no more than 2 inches deep. Dispose of cooled ash in household trash per local rules. Do not use it as fertilizer. 

Can I run it from solar or a generator?

Technically yes, but we don't advise it. If your system supplies the continuous wattage on a dedicated 20 A circuit. Plan around 1.5 to 2.0 kWh per cycle. 

Where can I install it and what clearances are needed?

Cabins, basements, bunkies, boats, RVs, and more. Allow room on the right side to operate the pedal and follow the manual’s clearance notes.

What is the warranty?

3 years on toilets having regular use and maintenance.

Do you offer pickup?

Pickup is available from our Beamsville showroom or our warehouse terminal, stock dependent.

Is Incinolet approved in my area?

Although CSA approved, requirements vary by province and municipality. Treat it as an electrical appliance install and check with your local Authority Having Jurisdiction and a licensed electrician.  diction and a licensed electrician.  

Shipping and delivery

Every Incinolet toilet includes free shipping anywhere in Canada except Yukon, Northwest Territories, and Nunavut, for a flat shipping fee of $250.00.

Delivery Times

  • 2–5 business days
  • 2–7 business days

Parts & Accessories

Replacement parts and bowl liners ship via UPS and are subject to standard shipping fees.

Remote or Limited Addresses

If your shipping address is not accessible, please arrange delivery to the nearest post office, courier pickup point, or freight terminal.

Please note: we cannot ship to PO Boxes.

Purchase Orders

Purchase orders are accepted. Include your PO number in the order notes when checking out, and a PDF invoice will be provided after purchase.

Additional Information
Shipments should be inspected on arrival. Please notify us within 48 hours of any damage.

For freight deliveries, carriers may contact you to arrange a delivery time.

Weather and regional conditions can extend transit times, we recommend ordering early if you have a deadline.

Quantity

Keep your 120V Incinolet running smoothly for the long haul with this 5–10 year maintenance bundle. It groups the most common wear items into one convenient package so you can service heat, airflow and safety controls in a single refresh, helping maintain clean burns and low odour when installed and vented correctly.

 

What’s Included

Incinolet Replacement Heater Element; HEA044 (120V)

Incinolet Replacement Blower Motor 120V; MOT006. 

Incinolet Replacement Blower Wheel Kit; WHE002S. 

Incinolet Replacement ITS Blower Thermostat, F130; THE014. 

Incinolet Replacement TS Spades Thermostat, L300; THE012. 

Incinolet Replacement STS Safety Thermostat, L140; THE013. 

Incinolet Replacement Thermocouple; THE009. 

Incinolet Replacement Ashpan, Large; PAN023

Incinolet Bowl Liners, Pre-folded, Box of 400. 

 

Key Features

All-in-one 120V upkeep set, covers heat, airflow and safety controls to reduce downtime. 

Parts and titles match the Incinolet Canada catalogue for easy reordering and customer clarity. 

Includes a full box of 400 pre-folded liners to keep daily use tidy and low-odour. 

 

Compatibility

For 120V Incinolet units; confirm voltage on the data plate and use the heater’s serial-range guidance to select HEA044 correctly. 

Ashpan size varies by serial range; Large (PAN023) is included by default in this bundle, choose Small (PAN022) if your serial indicates the Small pan. 




Installation & Care, Quick Tips

Service with power disconnected. Replace heater and place the thermocouple tip against the lower heater coil to ensure accurate control. Clean the blower wheel and housing on a 3–6 month cadence for smooth airflow and reduced vibration. 

 

Specs

Voltage: 120V bundle

SKU: BUN005

 

FAQs

Why buy the bundle instead of parts one-by-one?

It groups the heater, motor, wheel and three thermostats with the thermocouple, ashpan and liners, matching the manufacturer’s 5–10 year package for convenience and savings. 


How do I be sure the heater and ashpan are right for my unit?

Match voltage and serial range for the heater, and use your serial number to confirm ashpan size before checkout. 

View full details