Incinolet Toilet Questions

What power does the Incinolet need?

A dedicated 20 amp circuit. Choose 120 V at about 2000 W or 240 V at about 3500 W.

How many people can it support full time?

120 V model is about 4 people, 240 V model is about 6 people.

Does it use water or need a septic system?

No. It incinerates waste using electric heat and vents outside. 

Do I need a bowl liner every time?

Yes, for every use. New units include one box of 200 liners. Bowl Liners can be purchased here.

How long is a cycle and can I use it during the cycle?

Heater runs about 60 to 75 minutes, the blower continues 20 to 40 minutes to cool. You can use it any time during a cycle, then press Start again. 

How much electricity per cycle?

About 1.5 to 2.0 kWh per full cycle. Example at $0.20 per kWh is roughly $0.30 to $0.40 per cycle. 

What can go in the toilet?

Human waste, toilet paper, and tampons. Do not burn trash or food. Use a liner each time. 

How do I vent it?

Horizontal or vertical to outdoors, end with a dryer flap or rain cap. If total run is over 10 feet or uses more than two elbows, increase to 6 inch pipe, 15 feet max. Do not vent into an attic or crawl space. 

Will there be odours?

Little to none with correct venting and by starting a cycle after each use. Overloading or poor venting can cause odor. 

What happens during a power outage?

If a cycle stops mid-burn you may notice smoke or odour. Open a window. When power returns the fan restarts to cool the unit. 

How often do I empty the ash and how do I dispose of it?

Empty when ash is light in color or no more than 2 inches deep. Dispose of cooled ash in household trash per local rules. Do not use it as fertilizer. 

Can I run it from solar or a generator?

Technically yes, but we don't advise it. If your system supplies the continuous wattage on a dedicated 20 A circuit. Plan around 1.5 to 2.0 kWh per cycle. 

Where can I install it and what clearances are needed?

Cabins, basements, bunkies, boats, RVs, and more. Allow room on the right side to operate the pedal and follow the manual’s clearance notes.

What is the warranty?

3 years on toilets having regular use and maintenance.

Do you offer pickup?

Pickup is available from our Beamsville showroom or our warehouse terminal, stock dependent.

Is Incinolet approved in my area?

Although CSA approved, requirements vary by province and municipality. Treat it as an electrical appliance install and check with your local Authority Having Jurisdiction and a licensed electrician.  diction and a licensed electrician.  

Shipping and delivery

Every Incinolet toilet includes free shipping anywhere in Canada except Yukon, Northwest Territories, and Nunavut, for a flat shipping fee of $250.00.

Delivery Times

  • 2–5 business days
  • 2–7 business days

Parts & Accessories

Replacement parts and bowl liners ship via UPS and are subject to standard shipping fees.

Remote or Limited Addresses

If your shipping address is not accessible, please arrange delivery to the nearest post office, courier pickup point, or freight terminal.

Please note: we cannot ship to PO Boxes.

Purchase Orders

Purchase orders are accepted. Include your PO number in the order notes when checking out, and a PDF invoice will be provided after purchase.

Additional Information
Shipments should be inspected on arrival. Please notify us within 48 hours of any damage.

For freight deliveries, carriers may contact you to arrange a delivery time.

Weather and regional conditions can extend transit times, we recommend ordering early if you have a deadline.

Quantity

Restore optimal airflow and odour control to your Incinolet with this 120V blower motor replacement. Designed for 120-volt Incinolet units, it powers fresh-air intake and exhaust during each burn cycle to help prevent overheating and ensure clean, efficient incineration. For correct fit, verify your toilet’s serial number and voltage on the data plate at the back, top-right of the unit. 

 

Compatible with the following serial numbers:

36070 - 39999

50000 - 59999

70000 - 79999

90000 - 99999

 

Key Features

Built for 120V Incinolet units, matches the 120V motor spec listed in the factory parts list (part no. MOT006). 

Restores proper ventilation to reduce smoke/odour and maintain safe temperatures during cycles. 

OEM-spec fit with serial-number matching; Incinolet recommends supplying your serial number to confirm the correct variant. 

Small/Large variants: certain serial ranges require a Small or Large motor plate; check your serial number before ordering. 

Reliable performance: if your blower hums but won’t start, bearings may be failing; replacing the motor typically resolves this. 

Cleaner burns & fewer odours: proper airflow helps the catalyst do its job and minimizes room or exterior odour. 

Peace of mind: aligns with the manufacturer’s maintenance guidance for safe, efficient operation. 

 

Compatibility

Voltage: 120V Incinolet models (check the data plate on the back, top-right). 

Part reference: 120V blower motor MOT006 per Incinolet parts list. 

Note for 208V units: these generally use 240V parts except the heater and the 120V blower motor MOT006 on certain serial ranges (S/N 4100 and up). Always confirm your serial number. 

 

What’s Included

1 × 120V blower motor assembly (MOT006)

Installation overview (see owner’s manual for full procedures and safety steps). 

 

Installation & Care (Quick Tips)

Unplug the unit before service.

Remove top panel and access panel; free the motor, swap, and reassemble per manual instructions.

Clean the blower wheel/housing periodically (every 3–6 months) to reduce noise and vibration. Do not get the motor wet. 

 

Specs

Voltage: 120 VAC

Part No.: MOT006 (manufacturer parts list designation) 

 

FAQs

How do I know this will fit my Incinolet?

Check the voltage and serial number on the data plate (back, top-right) and provide your serial number when ordering to confirm the correct variant. 


My blower hums but won’t spin, do I need this?

A humming motor often indicates worn bearings; the manual advises replacing the blower motor in this case. 


Do 208V units use this 120V motor?

Many 208V units (S/N 4100+) use 240V parts except for the heater and the 120V blower motor MOT006; confirm against your serial tag. 